Release Notes
Software Client for Windows 23.06
In addition to bug fixes and stability enhancements, the Software Client for Windows introduces the following:
Pre-session Client Interface is Now Localized
The pre-session interface language can now be changed. The client will automatically use the system's configured language if the language is supported. For more information and instructions for changing the language, see Language Support.
High Performance Client Mode is Now Default
The Software Client for Windows's high performance client mode is now enabled by default, and recommended for most users. Previously, this mode was available as a technology preview. The previous standard mode can still be enabled by switching to Standard Performance Mode, if desired. For more information, see Client Modes.
Simplified Login for Single-Desktop Users
When a connection has a single desktop available, the desktop is now automatically selected and authenticated, without requiring a desktop selection step.
Users with multiple desktops available will continue to select their desired desktop after authenticating the connection.
For instructions on creating a connection, connecting to a session, and managing remote desktops, see Connecting to Remote Desktops.
Collaboration Manager Opens from In-Session Menu
The Collaboration Manager can now be launched from a new Collaboration menu option in the Software Client for Windows's menu, in addition to launching from the system menu bar. For more information, see Sharing Your Session With Collaborators.
New Anyware Modes Information Dialog
Information related to PCoIP Ultra acceleration modes is now available via the Connection Health Indicator on the Software Client for Windows interface. A tooltip has been added next to Mode on the Anyware Health window, which opens the Anyware Modes dialog containing a brief description on the PCoIP Ultra acceleration modes.
PCoIP Ultra modes are configured on the PCoIP agent. For more information, see PCoIP Ultra Modes.
Bloomberg Keyboard Support
Bloomberg Keyboards 4 and 5 are now supported when connecting a Software Client for Windows to PCoIP Agents for Windows. For more information, see Bloomberg Keyboard Support.
Fixed issue with tilde keypress repeating
Anyware Client 23.06 for Windows fixes an issue when connecting from a Windows Client to a macOS agent where the tilde key [ ` ] would repeat until cancelled with CTRL-C.
Anyware Health may show Incorrect Color Space when in GPU Offload Mode
While in GPU Offload mode, the color space may incorrectly report as BGRA 8|8|8|8.
While in GPU offload mode, do not use the Anyware Health monitor to identify current color space.
Microphone Does not Function with Kaspersky Anti-Virus
On Windows Client running on a desktop with Kaspersky Anti-Virus installed, forwarding of a local microphone to the remote desktop may be blocked. If this happens, the microphone cannot be used in the PCoIP session and Kaspersky Anti-Virus shows that {}"{}Receiving the audio stream for the application is blocked."
The PCoIP Client must be whitelisted in Kaspersky Anti-Virus in order to allow the audio stream for the application to be forwarded. Refer to Kaspersky for instructions on how to whitelist an application for audio stream access.
The name of network shown in Anyware Health Monitor does not change during a session
In Anyware Health Monitor, the name of network shown will not change during a session even if the actual network changes.
For example, if an ethernet cable is pulled out and the system switches to WiFi, the name of network will not change in the Anyware Health Monitor display until the session is disconnected and reconnected.
When entering credentials, pressing Enter in Username field does not advance cursor to Password field
Pressing Enter on the Username field does not advance the text entry cursor to the Password field.
Use the Tab button or mouse to move from the Username field to the Password field.
Intel UHD driver causes Windows memory leak
Intel UHD driver version 30.0.101.2079 causes a memory leak with PCoIP Software Client for Windows. When this occurs, the client system will slow significantly and may require a restart to recover.
This issue impacts Intel Integrated GPUs when used with 4k (UHD) monitors.
Other driver versions may also have this issue.
To avoid this issue, install an Intel UHD driver that is not affected:
- Version 30.0.101.1069 or earlier, or
- version 31.0.101.3729 or later.
Updating the driver to a version that is not affected resolves the issue.
Resizing collaboration session window causes crash
Re-sizing the PCoIP Client window while participating in a PCoIP Ultra Collaboration session may cause the PCoIP client to crash.
Avoid re-sizing client window size while participating in a PCoIP Ultra Collaboration session.
If this occurs, re-start the collaboration session by sending a new invitation to the Guest Collaborator.
Audio Input from microphone may stop after a long period of inactivity.
The microphone for a remote session may stop working if not used for a long period of time.
Audio output may stop working when switching devices
After switching to a different audio output device while connected to a remote desktop, audio output from the PCoIP client may stop.
Disconnect and reconnect the session after switching audio devices.
Audio disappears when audio-in is enabled
Audio output to speakers or a headset would stop after using audio input from a microphone.
Keyboard and Mouse Freeze when Connected to Remote Workstation Card in Windowed Mode
Keyboard and Mouse can freeze when connected to a Remote Workstation Card while the Soft Client is in windowed mode.
If this occurs, switch the client to full-screen mode to reestablish Keyboard and Mouse functionality.
Audio output may randomly stop
While connected to a remote desktop the audio output on the PCoIP client may stop.
Disconnect and reconnect the session after switching audio devices.
USB driver conflicts with NoMachine software
The USB driver installed with the PCoIP Software Client for Windows has a driver conflict with the USB driver used by the NoMachine remoting software.
Remove the NoMachine software before installing the PCoIP client.
Difficulty in exceeding 150Mbps throughput on Windows
On an otherwise clean, high-bandwidth capable network, a Windows client may experience sufficient PCoIP packet loss to limit throughput to approximately 150Mbps.
Windows Update and/or NIC driver updates can reconfigure settings such that UDP throughput is affected. Always ensure the latest drivers from the manufacturer are being used, as well as ensure that Flow Control and Interrupt Moderation are enabled for the NIC used to establish any PCoIP sessions. (These can be found the NIC's Advanced Properties tab within Windows' Device Manager.)
Bridged USB devices disconnected when switching to Windowed Mode
When the client has more than one monitor, switching from Full-screen to Windowed mode will disconnect all bridged USB devices.
Incompatibility between PCoIP Software Client for Windows and virtual KVM application Synergy
There is a known incompatibility between PCoIP Software Client for Windows and the virtual KVM application Synergy (http://symless.com/synergy). The Synergy application can interfere with the keyboard handling of the PCoIP client and cause sometimes a single or no keypresses to be transmitted to the PCoIP agent. This issue was observed with Synergy 2016 and may be present with other Synergy releases.
Disable Synergy when using the PCoIP client.
Wacom Intuos Pro and Intuos 5 tablets cannot be bridged
These tablets work as a pointing device when a session is not active, and when the tablet is not bridged while a session is active. When the tablet is bridged, the device manager application running on the remote host displays a warning icon next to the tablet and the tablet does not work.
Intuos PTH-660 and PTH-860 tablets are not impacted by this issue.
Avoid bridging Intuos Pro and Intuos 5 tablets.
Cancelling large USB file transfer fails
Cancelling a large file from being copied to, or from, a USB flash drive while bridged in PCoIP Software Client fails to function. The file will continue to copy until finished.
Allow operations on USB devices to complete prior to disconnecting the session.
SanDisk Cruzer USB devices do not work if the PCoIP session is disconnected while a file transfer is in progress
SanDisk Cruzer USB devices do not successfully re-bridge after the PCoIP session was disconnected during an active file transfer.
Avoid disconnecting the device or the session while file transfers are in progress. If a disconnection does occur while transfers are in progress, physically unplug and reconnect the device to the client. If the device fails to mount as a mass storage device after the previous step:
- Find the SanDisk Cruzer in Device Manager.
- Right-click on the device and select Uninstall.
- After uninstall completes, physically unplug and reconnect the device to the client.
USB keyboards do not work in bridged mode
Keyboards do not work when bridged. This affects both Windows and macOS PCoIP Software Client.
Do not bridge the keyboard. Keyboards function correctly when locally terminated.
Client window size is not remembered when crossing multiple monitors
When stretching the client window across multiple monitors, client window size is not remembered for session reconnects.
Mouse out of sync due to scaling in dual high-resolution displays
Connecting a PCoIP Software Client session with dual high-resolution displays in full-screen mode (2560x1600 for example) to a hard host that does not support high-resolution displays may result in unexpected behavior. For example, one or both displays may be scaled to single link DVI resolutions without the client also scaling, resulting in unsynchronized mouse movement.
Set client desktop to single link DVI resolutions. Alternatively, upgrade host GPU to support dual-link resolutions (Tera2 hosts only)
Audio input in PCoIP Software Client with PCoIP Remote Workstation Card does not work
When in session with a PCoIP Remote Workstation Card, PCoIP Software Client supports audio out from the host, but not audio into the host.