Release Notes

Software Client for Windows 23.12.8

Release 23.12.8 of the Software Client for Windows is a maintenance release which replaces and deprecates 23.12.6.

It includes the following:

  • Bug fixes and security updates.

Previous release information:

Release 23.12.6 of the Software Client for Windows is a maintenance release which replaces and deprecates 23.12.2.

It includes the following:

  • Bug fixes and security updates.

Previous release information:

Release 23.12 of the Software Client for Windows includes:

Introducing Zoom VDI for HP Anyware

Version 23.12 of the Software Client for Windows supports Zoom VDI for HP Anyware, which allows for an enhanced video conferencing performance in HP Anyware environments. The feature works by offloading the audio and video streams from HP Anyware agent devices to HP Anyware client devices, which handle the processing and transmitting of these streams to and from Zoom servers. This results in reduced latency, and improved meeting experience during PCoIP sessions.

Once installed and configured, the capabilities of Zoom VDI for HP Anyware enable quick adoption, leading to a seamless experience while starting and joining meetings. The Zoom VDI Plugin is similar to the Standard Zoom Client, and includes features such as optional end-to-end encryption, gallery view, speaker view, language interpretation, breakout rooms, and screen sharing.

Resolved Issues

None.

Known Issues

Caps Lock Key Press Events Are Not Synchronized When Using a JIS Layout Keyboard

 
194012

Caps Lock press events on a Japanese Industrial Standard (JIS) Layout keyboard connected to a client machine are not synchronized on the agent machine if the Caps Lock key is pressed outside the PCoIP session (for example, when the PCoIP client window is minimized). This happens because on JIS Layout keyboards, the Caps Lock key, or the Eisu (英数) key is used to toggle between English and Japanese input.

Workaround:

If a JIS Layout keyboard is connected on the client machine, do one of the following:

  • Before establishing the PCoIP session, set the input language to a language other than Japanese.
  • During an active PCoIP session, if a Caps Lock press event becomes unsynchronized, disconnect from the session, and connect again.
  • When a PCoIP session is minimized, DO NOT press the Caps Lock key outside of the PCoIP client window.

Incorrect Display of Color Space on Anyware Health Window

 
186953

When the PCoIP Ultra GPU Offload mode is enabled, the BGRA color space might incorrectly display as BGRA 8|8|8|8 on the Anyware Health window.

Workaround:

When the PCoIP Ultra GPU Offload mode is enabled, DO NOT use the Anyware Health window to identify current color space.

Microphone Does not Function with Kaspersky Anti-Virus

 
171686

On Windows Client running on a desktop with Kaspersky Anti-Virus installed, forwarding of a local microphone to the remote desktop may be blocked.  If this happens, the microphone cannot be used in the PCoIP session and Kaspersky Anti-Virus shows that {}"{}Receiving the audio stream for the application is blocked."

Workaround:

The PCoIP Client must be whitelisted in Kaspersky Anti-Virus in order to allow the audio stream for the application to be forwarded.  Refer to Kaspersky for instructions on how to whitelist an application for audio stream access.

The name of network shown in Anyware Health Monitor does not change during a session

 
169411

In Anyware Health Monitor, the name of network shown will not change during a session even if the actual network changes.

For example, if an ethernet cable is pulled out and the system switches to WiFi, the name of network will not change in the Anyware Health Monitor display until the session is disconnected and reconnected.

When entering credentials, pressing Enter in Username field does not advance cursor to Password field

 
166593

Pressing Enter on the Username field does not advance the text entry cursor to the Password field.

Workaround:

Use the Tab button or mouse to move from the Username field to the Password field.

Intel UHD driver causes Windows memory leak

 
166151

Intel UHD driver version 30.0.101.2079 causes a memory leak with PCoIP Software Client for Windows. When this occurs, the client system will slow significantly and may require a restart to recover.

This issue impacts Intel Integrated GPUs when used with 4k (UHD) monitors. 

Other driver versions may also have this issue.

Workaround:

To avoid this issue, install an Intel UHD driver that is not affected:

  • Version 30.0.101.1069 or earlier, or
  • version 31.0.101.3729 or later.

Updating the driver to a version that is not affected resolves the issue.

Resizing collaboration session window causes crash

 
165911

Re-sizing the PCoIP Client window while participating in a PCoIP Ultra Collaboration session may cause the PCoIP client to crash.

Workaround:

Avoid re-sizing client window size while participating in a PCoIP Ultra Collaboration session.

If this occurs, re-start the collaboration session by sending a new invitation to the Guest Collaborator.

Audio Input from microphone may stop after a long period of inactivity.

 
165119

The microphone for a remote session may stop working if not used for a long period of time.

Audio output may stop working when switching devices

 
162229

After switching to a different audio output device while connected to a remote desktop, audio output from the PCoIP client may stop.

Workaround:

Disconnect and reconnect the session after switching audio devices.

Audio disappears when audio-in is enabled

 
161387

Audio output to speakers or a headset would stop after using audio input from a microphone.

Keyboard and Mouse Freeze when Connected to Remote Workstation Card in Windowed Mode

 
159715

Keyboard and Mouse can freeze when connected to a Remote Workstation Card while the Soft Client is in windowed mode.

Workaround:

If this occurs, switch the client to full-screen mode to reestablish Keyboard and Mouse functionality.

Audio output may randomly stop

 
159438

While connected to a remote desktop the audio output on the PCoIP client may stop.

Workaround:

Disconnect and reconnect the session after switching audio devices.

USB driver conflicts with NoMachine software

 
104742

The USB driver installed with the PCoIP Software Client for Windows has a driver conflict with the USB driver used by the NoMachine remoting software.

Workaround:

Remove the NoMachine software before installing the PCoIP client.

Difficulty in exceeding 150Mbps throughput on Windows

 
82427

On an otherwise clean, high-bandwidth capable network, a Windows client may experience sufficient PCoIP packet loss to limit throughput to approximately 150Mbps.

Workaround:

Windows Update and/or NIC driver updates can reconfigure settings such that UDP throughput is affected. Always ensure the latest drivers from the manufacturer are being used, as well as ensure that Flow Control and Interrupt Moderation are enabled for the NIC used to establish any PCoIP sessions. (These can be found the NIC's Advanced Properties tab within Windows' Device Manager.)

Bridged USB devices disconnected when switching to Windowed Mode

 
54679

When the client has more than one monitor, switching from Full-screen to Windowed mode will disconnect all bridged USB devices.

Incompatibility between PCoIP Software Client for Windows and virtual KVM application Synergy

 
52396

There is a known incompatibility between PCoIP Software Client for Windows and the virtual KVM application Synergy (http://symless.com/synergy). The Synergy application can interfere with the keyboard handling of the PCoIP client and cause sometimes a single or no keypresses to be transmitted to the PCoIP agent. This issue was observed with Synergy 2016 and may be present with other Synergy releases.

Workaround:

Disable Synergy when using the PCoIP client.

Wacom Intuos Pro and Intuos 5 tablets cannot be bridged

 
41045

These tablets work as a pointing device when a session is not active, and when the tablet is not bridged while a session is active. When the tablet is bridged, the device manager application running on the remote host displays a warning icon next to the tablet and the tablet does not work.

Intuos PTH-660 and PTH-860 tablets are not impacted by this issue.

Workaround:

Avoid bridging Intuos Pro and Intuos 5 tablets.

Cancelling large USB file transfer fails

 
40817

Cancelling a large file from being copied to, or from, a USB flash drive while bridged in PCoIP Software Client fails to function. The file will continue to copy until finished.

Workaround:

Allow operations on USB devices to complete prior to disconnecting the session.

SanDisk Cruzer USB devices do not work if the PCoIP session is disconnected while a file transfer is in progress

 
40769

SanDisk Cruzer USB devices do not successfully re-bridge after the PCoIP session was disconnected during an active file transfer.

Workaround:

Avoid disconnecting the device or the session while file transfers are in progress. If a disconnection does occur while transfers are in progress, physically unplug and reconnect the device to the client. If the device fails to mount as a mass storage device after the previous step:

  1. Find the SanDisk Cruzer in Device Manager.
  2. Right-click on the device and select Uninstall.
  3. After uninstall completes, physically unplug and reconnect the device to the client.

USB keyboards do not work in bridged mode

 
40580

Keyboards do not work when bridged. This affects both Windows and macOS PCoIP Software Client.

Workaround:

Do not bridge the keyboard. Keyboards function correctly when locally terminated.

Client window size is not remembered when crossing multiple monitors

 
32597

When stretching the client window across multiple monitors, client window size is not remembered for session reconnects.

Mouse out of sync due to scaling in dual high-resolution displays

 
29862

Connecting a PCoIP Software Client session with dual high-resolution displays in full-screen mode (2560x1600 for example) to a hard host that does not support high-resolution displays may result in unexpected behavior. For example, one or both displays may be scaled to single link DVI resolutions without the client also scaling, resulting in unsynchronized mouse movement.

Workaround:

Set client desktop to single link DVI resolutions. Alternatively, upgrade host GPU to support dual-link resolutions (Tera2 hosts only)

Audio input in PCoIP Software Client with PCoIP Remote Workstation Card does not work

 
26355

When in session with a PCoIP Remote Workstation Card, PCoIP Software Client supports audio out from the host, but not audio into the host.