How do I copy a database from PCoIP Management Console 2.x if the web interface is not available?
In the event you cannot log into the web interface of PCoIP Management Console 2.x yet you need the database for recovery. Here are some steps to help move the database file from one MC to another. Note: Both PCoIP Management Consoles must be running the …
DNS errors in the event log of the PCoIP Zero Client running firmware 5.x and 6.x.
Problem The PCoIP Zero Client event log contains these entries ever 5 minutes. -510    MGMT_DISC_DNS :conduct_dns_record_search: ( DNS SRV: CMS ) DNS record not found -510    MGMT_DISC_DNS :conduct_dns_record_search: ( DNS SRV: Config Tool ) DNS record …
How does competing traffic on the network affect PCoIP performance?
This article outlines how other types of network traffic may negatively impact PCoIP performance. Please refer to  Network session checklist for PCoIP protocol LAN and WAN deployments  for more details on network configuration. On most modern LAN's, …
Why do USB 2.0 or isochronous devices fail to work as expected when plugged into a Samsung NC220 or NC240 PCoIP monitor?
Answer: This occurs because on the NC220 and NC240 monitor series, USB Ports 0, 1 and 2 are brought out directly and port 3 is connected to an internal hub. On this hub, 1 hub port is connected to a RS232 device, and another hub port is connected to an …
How do I improve performance when dragging a window on the screen using firmware pre-4.1.0 and without a PCoIP Hardware Accelerator installed?
Problem While there are many factors that determine desktop performance - see  PCoIP TROUBLESHOOTING STEPS: VMware View Virtual desktop performance  - lower performance of window dragging may be observed in the following environment: VMware Horizon View …
How to configure a PCoIP Zero Client to auto-connect to a Remote Workstation Card
Answer: To enable auto connect, you need to peer the PCoIP Zero Client to the Remote Workstation Card. You will need the IP and MAC of the host. You enter this in the PCoIP Zero Client's configuration (On Screen Display or Administrative Web Interface), …
Connecting a new PCoIP Zero Client to an existing PCoIP Remote Workstation Card.
In general, newer firmware in PCoIP Remote Workstation Cards (host cards) are backward compatible with PCoIP Zero Clients using older firmware. However, enhancements to firmware may produce unexpected behaviors. Important changes are documented in each …
Why do I still see VDM Server Address Cache addresses after clearing the Trusted Connection Server Cache?
Answer: The VDM Server Address Cache is a list of servers that are populated either manually from the AWI and OSD or via a Profile push from the Management Console. This field value can be set to either Last Server Used or Read Only. If set to Last Server …