Initiating the Broker Connection Flow¶
Initiating the Broker Connection workflow is a two-step process. As a first step, update the login_info.txt file. Then, run the broker_client_example using login_info.txt
as an argument. Use the -l
switch to invoke the session client, without the 60-second connect tag window.
-
Open Command Prompt and change the directory to bin.
-
Run the command line client, providing the
login_info.txt
file as an argument:broker_client_example -i login_info.txt -l
A status message will be displayed indicating whether the connection was successful.
The following code snippet is an example of the status message:
Connected Successfully.
Desktop ID : sal-w7p64-sa15.autolab.local
ip_addr : 10.64.60.147
port : 4172
connect_tag:
SCS1fw0Zbk+Eu7q2iz0/M7mxfEE52au/3Jedtgp16L/rA8iB00+Er+YJd0yIL0xd9M
v5V0CDLSDmUNkOCwyyV1+u3w1aA7hXxEWmzhAA
session_id : 2305843009213693954
sni : SAL-W7P64-SA15
URI: "teradici-pcoip://10.64.60.147:4172?sessionid=
2305843009213693954&sni=SAL-W7P64-SA15", PARAMETERS: "connect-tag=SCS1fw0Zbk%2bEu7q2iz0%2fM7mxfEE52au%2f3Jedtgp16L%2frA8iB00%2bE
r%2bYJd0yIL0xd9Mv5V0CDLSDmUNkOCwyyV1%2bu3w1aA7hXxEWmzhAA"